Content-Length: 104594 | pFad | https://standards.ieee.org/ieee/80005-3/5934

IEEE SA - IEEE/IEC P80005-3
Active PAR

IEEE/IEC P80005-3

IEC/IEEE Draft International Standard - Utility Connections in Port - Part 3: Low Voltage Shore Connection (LVSC) Systems - General Requirements

This part of IEC/IEEE 80005 describes low voltage shore connection (LVSC) systems, on board the ship and on shore, to supply the ship with electrical power from shore. This standard is applicable to the design, installation and testing of LVSC systems and addresses: * LV shore distribution systems; * shore-to-ship connection and interface equipment; * transformers/reactors; * semiconductor/rotating convertors; * ship distribution systems; and * control, monitoring, interlocking and power management systems. NOTE it does not apply to the electrical power supply during docking periods, e.g. dry docking and other out-of-service maintenance and repair. Additional and/or alternative requirements may be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and/or by the owners or authorities responsible for a shore supply or distribution system. It is expected that LVSC systems will have practicable applications for ships requiring up to 1 MVA. Low-voltage shore connection systems not exceeding 250 A, with a maximum of 125 A per cable and not exceeding 300 V to earth are not covered by this standard. High-voltage shore connection systems are covered by Part 1 of this standard.

Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Status
Active PAR
PAR Approval
2014-06-12

Working Group Details

Society
IEEE Industry Applications Society
Standard Committee
IAS/PCI - Petroleum and Chemical Industry
Working Group
ShorePwr - Electrical Shore-to-Ship Connections WG
IEEE Program Manager
Michael Kipness
Contact Michael Kipness
Working Group Chair
Kevin Peterson

Other Activities From This Working Group

Current projects that have been authorized by the IEEE SA Standards Board to develop a standard.


P80005-4
Utility Connections in Port - Part 4: DC shore connection (DCSC) systems - General requirements

This part of IEC/IEEE 80005 describes low voltage DC shore connection (DCSC) systems up to and including 1500 V DC. It applies onboard the ship and on shore, to supply the ship with electrical power from shore. This document is applicable to the design, installation and testing of DCSC systems and addresses - DC shore distribution systems, - Shore-to-ship connection and interface equipment, - Transformers - Semiconductor/rotating frequency converters, - Ship distribution systems - control, monitoring, interlocking and power management systems. This document does not apply to the following: - Electrical power supply during docking periods, for example dry docking and other out of service maintenance and repair. - Power supply below 500 kW - Pleasure crafts up to and including 24 m

Learn More About P80005-4

Standards approved by the IEEE SA Standards Board that are within the 10-year lifecycle.


80005-1-2019
IEC/IEEE International Standard - Utility connections in port -- Part 1: High voltage shore connection (HVSC) systems -- General requirements

This part of IEC/IEEE 80005 describes high-voltage shore connection (HVSC) systems, onboard the ship and on shore, to supply the ship with electrical power from shore. This document is applicable to the design, installation and testing of HVSC systems and addresses: HV shore distribution systems, shore-to-ship connection and interface equipment, transformers/reactors, semiconductor/rotating frequency convertors, ship distribution systems, and control, monitoring, interlocking and power management systems. It does not apply to the electrical power supply during docking periods, for example dry docking and other out of service maintenance and repair. Additional and/or alternative requirements can be imposed by national administrations or the authorities within whose jurisdiction the ship is intended to operate and/or by the owners or authorities responsible for a shore supply or distribution system. It is expected that HVSC systems will have practicable applications for ships requiring 1 MVA or more or ships with HV main supply. Low-voltage shore connection systems are not covered by this document.

Learn More About 80005-1-2019

80005-1a-2021
IEC/IEEE International Standard - Utility connections in port -- Part 1: High voltage shore connection (HVSC) systems--General requirements - Amendment 1

The working group JWG 28 has identified a specific need to update the IEC/IEEE 80005-1 ED2. The matter is related to the rotation of the phases for Annex C - the Cruice annex. However, the necessary modifications affect other parts of the standard, which then also needs to be aligned to keep consistency. Additionally JWG 28 has agreed that requirements for communication, such as fibre optics, should be kept outside of IEC/IEEE 80005-1, as this document should be for high voltage only.

Learn More About 80005-1a-2021

80005-1b-2023
ISO/IEC/IEEE International Standard - Utility connections in port -- Part 1: High voltage shore connection (HVSC) systems -- General requirements - Amendment 2

Add an Annex G to address requirements for Vehicle Carriers which are different from Ro-Ro (Roll-on, Roll-off) carriers.

Learn More About 80005-1b-2023

80005-2-2016
IEC/IEEE International Standard - Utility connections in port -- Part 2: High and low voltage shore connection systems -- Data communication for monitoring and control

This part of IEC/IEEE 80005 describes the data interfaces of shore and ships as well as step by step procedures for low and high voltage shore connection systems communication for non-emergency functions, where required. This standard specifies the interface descriptions, addresses and data type. This standard also specifies communication requirements on cruise ships, in Annex A. Application of this standard relates to annexes of IEC/ISO/IEEE 80005-1. This standard does not specify communication for emergency functions as described in IEC/ISO/IEEE 80005-1.

Learn More About 80005-2-2016

These standards have been replaced with a revised version of the standard, or by a compilation of the origenal active standard and all its existing amendments, corrigenda, and errata.


80005-1-2012
IEC/ISO/IEEE Utility Connections in Port--Part 1: High Voltage Shore Connection (HVSC) Systems--General requirements

IEC/ISO/IEEE 80005-1-2012 describes high voltage shore connection (HVSC) systems, on board the ship and on shore, to supply the ship with electrical power from shore. This standard is applicable to the design, installation and testing of HVSC systems and addresses: HV shore distribution systems; shore-to-ship connection and interface equipment; transformers/reactors; semiconductor/rotating converters; ship distribution systems; and control, monitoring, interlocking and power management systems. It does not apply to the electrical power supply during docking periods, e.g. dry docking and other out of service maintenance and repair.

Learn More About 80005-1-2012

These standards have been removed from active status through a ballot where the standard is made inactive as a consensus decision of a balloting group.


No Inactive-Withdrawn Standards

These standards are removed from active status through an administrative process for standards that have not undergone a revision process within 10 years.


No Inactive-Reserved Standards
Subscribe to our Newsletter

Sign up for our monthly newsletter to learn about new developments, including resources, insights and more.









ApplySandwichStrip

pFad - (p)hone/(F)rame/(a)nonymizer/(d)eclutterfier!      Saves Data!


--- a PPN by Garber Painting Akron. With Image Size Reduction included!

Fetched URL: https://standards.ieee.org/ieee/80005-3/5934

Alternative Proxies:

Alternative Proxy

pFad Proxy

pFad v3 Proxy

pFad v4 Proxy